Máy làm mát dầu coolant Daikin AKJ569

Phân loại: MÁY LÀM MÁT DẦU COOLANT

Mã hàng: AKJ569

Máy làm mát dầu coolant Daikin AKJ569 ( Model cũ AKZJ568 )

Giao hàng tận nơi và nhanh chóng
Freeship cho đơn hàng trên dưới 15km
Thu tiền tại nhà, đảm bảo an toàn.
Đổi trả hàng trong 7 ngày, thủ tục đơn giản.
HOTLINE: 0915281345

Máy làm mát dầu coolant Daikin AKJ569

 

Product Info

 AKZJ569

Further evolution of temperature control. Expansion of cooling capacity control range. ROHS compliant. High-energy saving performance. Low noise operation in the low-load range. Compact design. Easy monitoring of operating status.

Cross Reference
Kanto Seiki – KTV-15, V1500
Habor – HK-1000S
MAC – MAC-150CSC-SR, MAC-150CSC-SDX-SA
Please contact us for exact specifications when using cross-references.

Specifications

AKJ189, AKJ359, AKJ459

*1.
The cooling capacity indicates the value at the standard point (tank fluid temperature: 35°C, room temperature: 35°C, fluid used: ISO VG32). This unit has about ±5% of product tolerance.
*2.
Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the machine. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us.
*3.
There are the following three types of different voltage specifications.
AC220, 230 V : Option code −046 (without transformer)
AC380, 400, 415 V : Option code −047 (with built-in transformer)
AC440, 460, 480 V : Option code −048 (with built-in transformer)
The main circuit voltage is the transformer’s secondary side voltage of AC 200 V, 50/60 Hz. (−046 units have no transformer and therefore have the same external dimensions and mass as standard units. Their main circuit voltage is 220/230 VAC, 50/60 Hz.)
*4.
The optional thermistor for machine temperature synchronization is required. (Refer to Page 17 for details.)
*5.
The SDS (Safety Data Sheet) of refrigerant R410A is attached to the -C type.
*6.
Electric component box ingress protection: IP54 or equivalent (However, use piping conduits etc. rated at least IP54 at wiring ports.)
*7.
The molded-case circuit breaker is not supplied with this product. Please prepare it yourself.
*8.
The maximum power consumption/maximum current consumption of different voltage specifications are shown in the tables below.

■AKJ189

■AKJ359

■AKJ459

AKJ569, AKJ909, AKJ1509

*1.
The cooling capacity indicates the value at the standard point (tank fluid temperature: 35°C, room temperature: 35°C, fluid used: ISO VG32). This unit has about ±5% of product tolerance.
*2.
Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the machine. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us.
*3.
There are the following three types of different voltage specifications.
AC220, 230 V : Option code −046 (without transformer)
AC380, 400, 415 V : Option code −047 (with built-in transformer)
AC440, 460, 480 V : Option code −048 (with built-in transformer)
The main circuit voltage is the transformer’s secondary side voltage of AC 200 V, 50/60 Hz. (−046 units have no transformer and therefore have the same external dimensions and mass as standard units. Their main circuit voltage is 220/230 VAC, 50/60 Hz.)
*4.
The optional thermistor for machine temperature synchronization is required. (Refer to Page 17 for details.)
*5.
The SDS (Safety Data Sheet) of refrigerant R410A is attached to the -C type.
*6.
Electric component box ingress protection: IP54 or equivalent (However, use piping conduits etc. rated at least IP54 at wiring ports.)
*7.
The molded-case circuit breaker is not supplied with this product. Please prepare it yourself.
*8.
The maximum power consumption/maximum current consumption of different voltage specifications are shown in the tables below.

■AKJ569

■AKJ909

■AKJ1509